Air quality monitoring system
Compact air
quality monitoring
Flexible at
point of interest
Modular configuration
2 of Pollutants Standard modules
Dimensions (H/W/D, w/o handle and sample inlets) | 890/782/400 mm35/30.8/15.8 in. |
Weight | 65.8 kg/145.1 lbs |
Power consumption* | max. 670 W |
Flow | <2000ccm/min +2000 ccm/min for nephelometer |
- Construction:
Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
Rugged, inconspicuous burglar-proof design - Standard equipment:
Internal air conditioning and temperature control
Maintenance door
Cylinder lock (standard)
Zero air supply - Operating temperature
-20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F) - Options
Various types of mounting bracketsWireless communication (GPRS, 3G,…)
Sample gas conditioning (high relative humidity, high PM exposure)
Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)
4 of Pollutants Standard modules
Dimensions (H/W/D, w/o handle and sample inlets) | 1120/782/400 mm 44.1/30.8/15.8 in |
Weight | 73.9 kg/162.9 lbs |
Power consumption* | max. 670 W |
Flow | <3000ccm/min +2000ccm/min for nephelometer |
- Construction:
Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
Rugged, inconspicuous burglar-proof design - Standard equipment:
Internal air conditioning and temperature control
Maintenance door
Cylinder lock (standard)
Zero air supply - Operating temperature
-20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F) - Options
Various types of mounting bracketsWireless communication (GPRS, 3G,…)
Sample gas conditioning (high relative humidity, high PM exposure)
Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)
2 of Pollutants Standard modules
Type approved PM10 or PM2.5 monitor (Thermo 5030 SHARP, Met One BAM1020)
Dimensions (H/W/D, w/o handle and sample inlets) | 1200/782/615 mm 47.2/30.8/24.2 in. |
Weight | 110 kg/242.5 lbs |
Power consumption* | max. 1100 W |
Flow | <2000ccm/min +16.7l/min for PM monitor |
- Construction:
Well-isolated double aluminium constructionStandard monitoring modules on removable drawers
Rugged, inconspicuous burglar-proof design - Standard equipment:
Internal air conditioning and temperature control
Maintenance door
Cylinder lock (standard)
Zero air supply - Operating temperature
-20 °C/-4°F to +42 °C/108°F (optional heating for down to -40 °C/-40°F) - Options
Various types of mounting bracketsWireless communication (GPRS, 3G,…)
Sample gas conditioning (high relative humidity, high PM exposure)
Integration of external devices and instruments (e.g. 4-20 mA, RS-232, Modbus via IP,…)
Solutions to communicate with external data systems (e.g. TCP-IP, Modbus via IP, RS-232, 4-20 mA,…)
Various base frames and handling devices for on-site operation (roadside, workshop, indoor, pickup truck, trailer,…)
Pollutants Standard modules
Pollutant | Weight |
---|---|
NO/NO2/NOX | Weight: 12.0 kg/26.5 lbs optional: span module |
NH3 | Only combined with NOX module |
O3 | Weight: 5.8 kg/12.8 lbs,optional: span module |
SO2 (H2S) | Weight: 8.5 kg/18.7 lbs,optional: span module; optional: H2S module |
CO | Weight: 9.0 kg/19.8 lbs,optional: span module |
More sensor modules
- Photoionisation detector (PID) for volatile organic compounds (VOC)
- Nephelometer for indicative PM monitoring (PM10, PM2.5)
- Meteorological sensors: wind direction, wind velocity, temperature, air pressure, relative humidity, precipitation, made by various manufacturers
- Traffic data sensors: traffic count, made by various manufacturers
- Noise sensors, made by various manufacturers
- Electrochemical sensors for formaldehyde, ethane, chlorine…
- For industrial applications, environmental hygiene, and indoor air quality monitoring (IAQ)
- Sensors for monitoring indoor CO2 (IAQ)
- Navigation system (GPS) for linking monitoring data with geographical data